| INPUT Voltage..........................Wide range input 185-305V Frequency....................................................50/60Hz Line Regulation............+/-0.5 output variation over .............................................................full input range Power Factor..................................................> 0.99 Total Harmonic Distortion.........................< 10% OUTPUT Lamp Operating Frequency...155Hz Square Wave Lamp Current C.F............................................<1.3 Weight................................................................12 oz Case Material ..................................................Metal Transient Protection........................................Yes Short Circuit Protection.................................Yes Thermal Protection..........................................Yes Open Circuit / No Lamp / Hot Lamp Shutdown, Retry and Ignition Failure Protection............................................................Yes Ignition failure shutdown in 5 seconds followed by multiple timed restrikes with lamp ignition or timed shutdown until power is reset (restrike timing is lamp wattage dependent). Lamp Distance from Ballast...............Standard up to 50 ft. ......Distances beyond 50 ft. consult factory. Lead Lengths Side Lead Models ......................................8” Bottom Feed Models...............................10” Safety Standard............................................UL Listed |